Specifications
158
Alvium CSI-2 Cameras User Guide V2.8.1
1800 C-2050m/c
Power requirements
Power over MIPI CSI-2
Power consumption
(typical, at 5 VDC)
2.9 W
Storage temperature
-20 °C to +85 °C ambient temperature
Operating temperature
Hardware
option
Housing
Cooling areas
2
Mainboard
3
Bare board
4
Not applicable
-20 °C to +85 °C
+5 °C to +88 °C
Open housing
5
-20 °C to +65 °C
Relative humidity
0% to 80% (non-condensing)
Digital interface
MIPI CSI-2 D-PHY V1.1; 1, 2, or 4 lanes; maximum 1.051 Gbps per lane
Camera controls
GenICam V2.0 (GenICam for CSI-2 Access)
V4L2 controls (Video4Linux Access), Direct Register Access
2
See
3
Output by
DeviceTemperature
4
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
www.alliedvision.com/en/support
5
Temperature values must be observed for the housing
and
for the cooling areas.
Feature
Specification
Table 67: Alvium 1800 C-2050m/c specifications (sheet 2 of 2)