Specifications
176
Alvium CSI-2 Cameras User Guide V2.8.1
User sets
Supported features
UserSet
features enable to store individual settings on selected Alvium 1800 C
cameras. These user sets can be loaded by default, without needing to set values
by software after every restart of the camera. Or they can be used to switch
between different settings, for example, to adjust from daylight to artificial light.
User sets support all features except for:
• Selectors
• Command features
• Read-only features
• Features that do not apply to the corresponding interface, such as USB
related features on a CSI-2 camera
• Features in the
LUTControl
category.
Trigger features and UserSetDefault
Trigger features are reset to default values when the default user set is loaded.
Column
UserSetLoad
displays how user values are affected when the command
for
UserSetLoad
is executed.
Feature
Default value
UserSetDefault
TriggerActivation
RisingEdge
Default value
TriggerMode
Off
Default value
TriggerSelector
AcquisitionStart
User value
TriggerSoftware
[Command]
Not applicable
TriggerSource
Software
Default value
Table 79: Trigger features being reset
GenICam
for CSI-2
Access