Installing the AT-3624TRS in a non-managed hub configuration
The following procedure details how to install a sample rackmount
configuration in a non-managed chassis. This example assumes the
following:
❑
You are working with a two-slot rackmount chassis
❑
You will populate both slots in the chassis
❑
You will be working with two Slaves (NO Master or Backup)
1.
Remove the interrepeater bus dust cover on the back panel of the
module before installing the unit in a rackmount chassis.
2.
Remove the rubber feet from the Slaves
3.
Reinstall the screws once the rubber feet are off.
Attention
After removing the rubber feet, it is important to reinstall the screws or the
module will expand. (Also see Chapter 2, “Hardware Installation” on
page 7.)
4.
Attach the mounting bracket/handle assemblies to each side of the
Slave you are installing.
5.
Plug one end of the power cord into the Slave and the other end into
your power outlet.
6.
Check to see that the Power indicators on the Slave illuminates.
7.
Check to see that the Slave performs a self-test.
The Slave will temporarily illuminate all port LEDs in sequence,
beginning with port 1 and continuing with port 2, port 3 and so
forth. The self-test recurs until a port is connected.
8.
Align the backplane connector with the interrepeater bus connector on
the back panel of the Slave.
9.
Seat the interrepeater bus port of the Slave carefully in the backplane.
Attention
When inserting or removing hub modules, the power cord should remain
plugged in (using the hot swapping method). To use the hot swapping
method, the module must be disconnected from the backplane before the
power cord is unplugged. If a fault occurs (Fault light stays ON), disengage
the hub module from the backplane, unplug and replug the power cord, and
re-seat the module.