Error Codes
“
tP
”: The thermal protection on
the motor is open
Machine is possibly overloaded
The brakes not functioning properly
Transmission not functioning properly
Properly load the machine
Check the function of the brakes
Check the function of the transmission
To clear this error wait for “tP” to clear. The
control will then prompt user to press Start.
“
Er
” and “
Co
”: SCI Comm
Error
Error in the communication between the
front end control and the output board.
There is a break or disconnect in the
main harness to the two controls.
Check for any burnt pins in the connectors or
any disconnections in the harness.
To clear this error the machine must be
powered down.
“
Er
” and “
LE
”: Water Leak
Detection Error
Water level is dropping during the leak
detection step, if enabled.
Check mixing valve for leaks.
“
Er
” and “
Sd
”: Slow Drain
Detection Error
The machine is taking longer to drain
than a preset time, if enabled.
Check the tub and drain for leaks.
“
Er
” and “
nr
”: Drive Not
Ready Error
Output board is not ready within one
minute.
Replace the output board.
To clear this error the machine must be
powered down.
“
Ed
” and “
XX
”: Output Board
Error
Error received from the output board.
Inspecting wire harnesses to output board.
Replace output board if wiring is not damaged.
To clear this error the machine must be
powered down.
“
Er
” and “
bS
”: Board Shorted
Error
Output board enable relay is shorted.
Replace the output board.
To clear this error the machine must be
powered down.
“
PF
”: Delay Start Power Fail
Error
Machine experienced a long power fail
or has been unplugged during Delay
Start Mode.
No service should be needed.
Press Power/cancel to continue normal
operation.
Error Code
Possible Causes
Corrective Action