203562
41
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Test Procedures
29. Mixing Valve Solenoid Test Procedure
Mixing valve test procedures using an Ohm meter.
NOTE: Resistance readings slightly out of given ranges may be due to meter conditions. These readings DO
NOT necessarily indicate mixing valve failure.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
120 Volt coils
900 - 1100 Ohms
240 Volt coils
3200 - 4000 Ohms