Electrical Requirements
63
70458301ENR6
Electrical Specifications
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit.
NOTE: 3 Phase Only –
Each tumble dryer must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).
025, 030 and 035 Series Gas and Steam Models
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate Amps
Recommended Circuit
Nonreversing
Reversing
Breaker Rating
Wire Size
AWG (mm
2
)
120V/60Hz/1ph
L1, Neutral, and ground
12.0
N/A
15A – 1 pole
14 (2.5)
208-240V/60Hz/1ph
L1, L2, Neutral, and ground
6.7
N/A
10A – 2 pole
14 (2.5)
120V/60Hz/1ph
L1, Neutral, and ground
7.5**
N/A
10A – 1 pole
14 (2.5)
208-240V/60Hz/1ph
L1, L2, Neutral, and ground
4.5**
N/A
10A – 2 pole
14 (2.5)
100V/60Hz/1ph
L1, Neutral, and ground
11.0
N/A
15A – 1 pole
14 (2.5)
200-220V/60Hz/1ph
L1, Neutral, and ground
5.8
N/A
10A – 1 pole
14 (2.5)
100V/50Hz/1ph
L1, Neutral, and ground
12.1
N/A
20A – 1 pole
12 (4)
200V/50Hz/1ph
L1, Neutral, and ground
7.5
N/A
10A – 1 pole
14 (2.5)
230-240V/50Hz/1ph
L1, Neutral, and ground
7.5
N/A
10A – 1 pole
14 (2.5)
200-208V/60Hz/3ph
L1, L2, L3, and ground
3.2
4.0
10A* – 3 pole
14 (2.5)
240V/60Hz/3ph
L1, L2, L3, and ground
3.2
4.0
10A* – 3 pole
14 (2.5)
200V/50Hz/3ph
L1, L2, L3, and ground
2.9
3.5
10A* – 3 pole
14 (2.5)
230-240V/50Hz/3ph
L1, L2, L3, and ground
3.5
N/A
10A* – 3 pole
14 (2.5)
380V/50 or 60Hz/3ph
L1, L2, L3, and ground
1.5
2.0
10A* – 3 pole
14 (2.5)
400-415V/50Hz/3ph
L1, L2, L3, and ground
1.6
2.0
10A* – 3 pole
14 (2.5)
440V/60Hz/3ph
L1, L2, L3, and ground
1.6
N/A
10A* – 3 pole
14 (2.5)
460-480V/60Hz/3ph
L1, L2, L3, and ground
1.6
2.0
10A* – 3 pole
14 (2.5)
*
3 Phase machines should not have fuses, breakers only.
**
Special low Amp blower model, 025 Series only.
N/A = Not Applicable
Table 8