© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Installation
70458301ENR6
34
If lockout condition persists, check that the manual
gas shut-off valve is in the ON position and that the
gas service is properly connected. If condition still
persists, remove tumble dryer from service.
Models
Prepurge
Time
(seconds)
Trial for
Ignition
(seconds)
Reset
Lockout
Condition
By:
Mo
dels t
h
roug
h 3/10/13
CE and
Australia
18
10
025, 030,
035, 055:
Press reset
button on
rear of
machine
T30, T45:
Press lighted
reset button
in rear
contactor
box
All others
1-3
10
Open
loading door
Models st
arting
3/
1
1
/13
CE
1
10
(attempts to
ignite 3
times)
For models
with EO,
RE, RU or
UO control
suffixes:
Press start
on control
keypad.
For models
with all
other control
suffixes:
Press and
hold reset
button on
junction box
until light
goes out.
Non-CE
and non-
Australian
1
10
(attempts to
ignite 3
times)
Open
loading
door
Mode
ls
s
tar
ting
3/1
1
/13
thr
ough 7/3
1
/13
Australia
18
10
025, 030,
035, 055:
Press reset
button on
rear of
machine
T30, T45:
Press lighted
reset button
in rear
contactor
box
(Continued)
(Continued)
Models
Prepurge
Time
(seconds)
Trial for
Ignition
(seconds)
Reset
Lockout
Condition
By:
M
o
de
ls
s
tart
in
g
8/
1/
13
Australia
23
23
For models
with EO,
RE, RU or
UO control
suffixes:
Press start
on control
keypad.
For models
with all
other
control
suffixes:
Press and
hold reset
button on
junction box
until light
goes out.