© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Installation
70458301ENR6
30
Auxiliary Alarm
The fire suppression system provides an auxiliary
output signal when the system is activated. During
tumble dryer installation, you have the option to
connect a separate alarm system to this auxiliary
output. Potential uses of the auxiliary output include,
but are not limited to: (1) sounds an alarm, (2)
activates a building sprinkler system, (3) notifies a fire
department, etc. Use of the auxiliary output is not
required for the fire suppression system to operate, but
may be used for additional protection.
The connection to the auxiliary output is made through
the FS-1 and FS-2 fast-on connections inside the fire
suppression control box. Refer to
Figure 7
. The relay
is rated for 24 VAC, 5.2 Amp, sealed current.
Figure 7
To Reverse the Loading Door – 025,
030, 035 and 055 Series
The tumble dryer is delivered with a right hinged door,
but the door can be changed to a left hinged position.
1. Disconnect power supply to tumble dryer.
2. Unlock and remove control panel. Remove two
control assembly mounting screws from right
side. Swing open control. Refer to
Figure 8
.
3. Remove lint panel.
IMPORTANT: Support door and hinge assembly
securely to prevent it from dropping once side
screws are removed from door hinge lug.
Figure 8
TMB1999N
1
Opening for Auxiliary Alarm Cable
2
Fuse
3
Auxiliary Alarm Fast-On Connection
4
Test Button
5
Light
6
Reset Button
7
Auxiliary Alarm Fast-On Connection
TMB1999N
3
4
5
6
7
1
2
TMB2100N
1
Front Panel Screw
2
Front Panel
3
Control Panel
4
Control Assembly Screw
5
Control Assembly
6
Lint Panel
TMB2100N
1
6
5
4
2
3
1