© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Error Codes
95
202065R6
Table 14 (continued)
Display
Description
Cause/
Corrective Action
Right most
decimal
point Lit
Network Communication Error
Communication problem. Wait for 1.5 minutes for error
to clear. If error doesn’t clear, power-down and power-
up the machine. If error persists, replace control or
network board.
ALrn
Break-in Alarm Error
Service the door or coin vault switches.
oFF
Break-in Alarm Shutdown Error
Service the door or coin vault switches.
EFL
Fill Error
Pressure switch fails to open in 30 minutes (or other
programmed length of time) in any fill agitate cycle.
Edr
Drain Error
Water sensed at end of wash spin step or final spin step.
Err
Coin Error
Invalid coin pulse or inoperative coin sensor. Check coin
drop area and remove obstructions. If error persists,
tampering may have occurred. Evaluate security
procedures.
Table 14