Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(6) Press in on locking tabs of coin drawer
switch and remove switch through front of
meter case. Refer to Figure 16.
(7) Use a 7/16 inch socket with No. 310P4 1-4
inch Ratchet Extension Tool and remove
two locknuts holding coin drop to front of
meter case. Refer to Figure 16.
(8) Lift back end of coin drop and pull straight
back until bottom edge of the drop’s front
face plate falls behind the coin drawer
housing. Refer to Figure 17.
Figure 16
7/1
6
"
W494SE3A
FRONT OF METER
CASE
VELCRO
STRIPS
MULTIPLIER
1/4" RATCHET
NO. 310P4
1/4" RATCHET EXTENSION
TOOL
7/16" SOCKET
LOCKNUT
COIN DRAWER
SWITCH
Figure 17
W410SE3A
BACK END
OF COIN DROP
COIN DRAWER
HOUSING
COIN DROP
FRONT
FACE PLATE