Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
d. SINGLE COIN DROP REMOVAL
(1) Unlock and open service door.
NOTE: If screw type lock is used, the retainer
bracket must be removed from inside meter case.
(2) Disconnect wire harness from coin drawer
switch and disconnect coin drop at
disconnect plugs.
(3) Press in on locking tabs of service door
switch and remove switch from bracket on
meter case, as shown in Figure 13.
(4) Use a 7/16 inch socket with No. 310P4 1/4
inch Ratchet Extension Tool and remove
two locknuts holding coin drop to front of
meter case. Refer to Figure 14.
(5) Lift back end of coin drop and pull straight
back until bottom edge of drop’s front face
plate falls behind the coin drawer housing.
(6) Carefully lift complete coin drop straight
up and out of meter case.
e. SINGLE COIN DROP INSTALLATION
(1) Reverse removal procedures for
installation.
Figure 13
W408SE1B
SERVICE
DOOR SWITCH
LOCKING
TAB
METER
CASE
SWITCH
BRACKET
Figure 14
7/1
6
"
W485SE1A
LOCKNUT
7/16"
SOCKET
NO. 310P4
1/4" RATCHET
EXTENSION
TOOL
1/4"
RATCHET
FRONT
OF METER
CASE