© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operation
31
1300003 (EN)
Breakdown Procedures
Hot Finisher Stops Due to Power Failure
To separate the return ribbons from cylinder
immediately:
1. Insert the crank into the opening located on the
right panel of the finisher.
2. Turn the crank clockwise to rotate the cylinder.
Refer to
Figure 21.
3. Insert a thick and very wet cloth (hardly wrung
dry) into the finisher while rotating the cylinder
with the crank.
Figure 21
Finisher Won’t Start or Stops Suddenly
If the finisher won’t start and the cylinder won’t rotate
or has stopped suddenly, check if finger guard safety
panels or manual crank safety switch are activated.
Release the activated emergency stops, and
immediately start the finisher again by pressing the
green Power On button to prevent damage to return
ribbons.
Unusual Noises and Other Issues
If the finisher makes unusual noises (rubbing, banging,
etc.), or for any other problem contact a qualified
service person immediately.
Alarms
(Microprocessor Models Only)
An alarm will sound for abnormal conditions as shown
below.
Insufficient Air Flow (Gas Models Only)
When the pressure valve in the exhaust pipe opens for
two seconds or more, the alarm sounds for one minute
and display shows AL1.
On 3-Phase models, check the rotation direction of the
exhaust fans. If exhaust fans are rotating in wrong
direction, the electrical connection at L1, L2 or L3
terminals must be changed. If exhaust fans are rotating
in correct direction, disconnect gas exhaust pipe. If
alarm stops, exhaust pipe is too narrow or blocked.
Alarm is cancelled automatically when pressure
switch returns to normal position or when finisher is
turned off.
Emergency Safety Bar
Non-CE Models
When the emergency safety bar is activated, the
finisher automatically turns off and no message is
displayed.
Alarm is cancelled by moving emergency safety bar to
normal position and restarting finisher.
CE Models
When the emergency safety bar is activated, the
finisher automatically turns off, the alarm sounds for
one minute and display shows AL2.
Alarm is cancelled by moving emergency safety bar to
normal position and restarting finisher or turning
machine off and on.
Microprocessor Control
When there is an internal problem with the control, the
alarm sounds for one minute and display shows AL3.
Alarm is cancelled by restarting finisher or turning
finisher on and off.
FWF11N
FWF11N
NOTE: Side panel is removed for illustrative
purposes only. NEVER operate unit without
side panels.
Emergency safety bar is for your safety.
To avoid serious personal injury, do not
override emergency safety bar.
W548
WARNING