Section 7 Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
65. GAS VALVE COILS CHECK – SILICON
NITRATE IGNITION
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 7.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 7.
c. Close main gas shut-off valve.
d. Remove disconnect blocks from gas valve
coils.
e. Set test meter to read Ohms.
f. Both coils should read between 2400 and 2800
Ohms.
NOTE: If meter registers any other readings than
those listed, the respective coil(s) should be
replaced.
66. FLAME SENSOR CHECK – SILICON
NITRATE IGNITION
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 7.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 7.
c. Disconnect flame sensor wire at disconnect
block.
d. Set test meter to read Ohms.
e. Put first meter probe on terminal of flame
sensor wire and second meter probe on terminal
2 of disconnect block. See Figure 67.
f. If the meter does not show any reading (infinite
Ohms), there is no continuity. If there is no
continuity, replace igniter and sensor assembly.
IMPORTANT: Always examine all wires, terminals
and connectors to be sure wiring is proper before
replacing any components.
Figure 66
To reduce the risk of fire, explosion and
electric shock, close the valve in the gas
supply line to the gas dryer and disconnect
the electrical power unless gas or power
supplies are required to perform test
procedure.
W263
WARNING
D230PE2A
GAS VALVE
COILS