Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
i. Front Cylinder Seal (Figure 50)
When installing the cylinder seal, it is important
to remember these two important steps:
(1.) The stitching on the seal must face towards
center of dryer.
(2.) The short flap must be glued to the
bulkhead and the long flap left loose.
IMPORTANT: The replacement seal can be
adhered to the bulkhead using No. 22506P Sealant.
This is accomplished by applying a bead of sealant
around the entire flanged area where the felt seal
contacts the bulkhead.
Figure 50
BULKHEAD
LONG FLAP
SEAL STITCHING
(Must face towards
center of dryer)
SHORT FLAP
(Must be glued
to bulkhead)
D257SE3A