505039
75
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Section 7
Test Procedures
IMPORTANT: Electrical test procedures in this
service manual are performed by using a Volt-Ohm
meter. Tests can also be performed using a multi-
meter or any other electrical testing equipment with
which the service person is familiar.
57. DRIVE MOTOR
a. Remove motor and exhaust assembly. See
b. Disconnect motor wire harness at motor
disconnect block.
NOTE: Refer to appropriate wiring diagram when
rewiring motor switch.
NOTE: Drive Motor Resistance
120 Volt 2,460 – 3,100 Ohms
Figure 61
2
6
4
3
5
1
G
DRIVE
MOTOR
MOTOR AND
EXHAUST
ASSEMBLY
D326SE3A
1
2
4
6
5
3
MOTOR
DISCONNECT
BLOCK
MOTOR
SWITCH