505039
87
Section 7 Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
72. FABRIC SELECTOR SWITCH
a. Unlock control panel. See Figure 8A.
b. Pull top of control panel away from control
cabinet and lift up. See Figure 8B.
c. Remove control panel from control cabinet. See
Figure 8C.
d. Disconnect wires from fabric selector switch.
NOTE: Refer to wiring diagram when reconnecting
wires.
e. Set test meter to read Ohms and apply meter
probes to switch terminals.
73. TIMER CONTACTS (Nonmetered Models)
a. Unlock control panel. See Figure 8A.
b. Pull top of control panel away from control
cabinet and lift up. See Figure 8B.
c. Remove control panel from control cabinet. See
Figure 8C.
d. Disconnect wires from timer, except timer
motor wires.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
e. While supporting timer, remove screws holding
timer to control cabinet. See Figure 10.
f. Pull timer out through control panel opening as
far as wires will permit.
g. Manually rotate timer out of “OFF” position
and into cycle.
h. Set test motor to read Ohms. The following
readings should be found:
(1.) Motor circuit test – L1 and M = “zero”
Ohms (closed)
(2.) Heat circuit test – L1 and H = “zero” Ohms
(closed)
(3.) Timer motor test – L1 and N =
approximately 1100 Ohms or apply live
power to timer motor terminals and motor
should run.
NOTE: Timer Motor Resistance
120 Volt, 60 Hz2,460 – 3,100 Ohms
i. Rotate timer to “cooldown” (5 minutes before
“OFF”). “Infinite” (open) reading should be
found between L1 and H.
j. Rotate timer to “OFF” position. “Infinite”
(open) reading should be found between L1 and
M and between L1 and H.
NOTE: Timer motor power is supplied through M
terminal.
FABRIC SELECTOR SWITCH
–
4 Position
L1-1
L1-2
Fluff
–
–
Delicate
X
X
Perm. Press
–
X
Normal
–
X
X indicates closed
Figure 68
XXX VAC
L1
H
N
M
3 WATT
KI
NGSTON
D341SE1A
"L1"
"H"
"N"
GROUND
TERMINAL
TIMER
MOTOR
WIRES
"M"