505039
39
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
(8.) Lift back end of coin drop and pull straight
back until front edge of the drop’s front
face plate clears the two guide wires. See
Figure 23.
(9.) Carefully slide drop horizontally until drop
clears inside wall of control cabinet.
Remove drop through front opening of
control cabinet. See Figure 24.
b. Installation
(1.) Reinstall drop through front opening of
control cabinet. Gently lift the drop up onto
control cabinet’s coin vault. See Figure 25.
(2.) Carefully pull coin drop slightly up and
forward. Turn the outer side of coin drop’s
front face plate slightly to feel the outer
guide wire line up and enter the front face
plate’s lower hole. Gently tug coin drop
sideways to feel if the outer guide wire has
gone through the hole. See Figure 26.
Figure 23
Figure 24
D224SE1A
GUIDE
WIRES
COIN DROP
FRONT
FACE PLATE
D225SE1A
INSIDE WALL
OF CONTROL
CABINET
FRONT OPENING
OF CONTROL
CABINET
Figure 25
Figure 26
D226SE1A
CONTROL CABINET
COIN VAULT
D227SE1A
OUTER GUIDE
WIRE
FRONT
FACE PLATE
LOWER HOLE
FRONT
FACE PLATE
OUTER SIDE