Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
5. HEATING ASSEMBLY DOES NOT HEAT OR BURNER DOES NOT IGNITE
POSSIBLE CAUSE
TO CORRECT
Improper or inadequate exhaust system.
• See INSTALLATION INSTRUCTIONS (supplied with
dryer) for exhaust requirements.
Use of plastic or thin foil exhaust duct.
• Replace with solid or rigid flexible metal exhaust duct.
Blown house fuse or tripped circuit breaker.
• Check fuses or circuit breakers. A 240 Volt dryer uses two
fuses. Make sure both fuses are good.
Temperature selector switch set at FLUFF, or
inoperative.
• Reset or test switch and replace if inoperative.
Timer improperly set (set in a cool-down period, or
a no heat cycle).
• Reset timer. Try another cycle.
Inoperative limit thermostat.
• Test thermostat and replace if inoperative.
Inoperative drive motor switch.
• Test switch and replace if inoperative.
Electric Models: Inoperative heater assembly.
• Test heater assembly and replace if cold Ohms do not read
between 9 and 10.5 Ohms.
Electric Models: Inoperative thermal fuse.
• Test thermal fuse and replace if inoperative.
Gas Models: Insufficient gas supply.
• Check gas shut-off valve in dryer and main gas line valve.
• Open partially closed gas shut-off valve, or correct low
gas pressure.
Gas Models: Inoperative gas valve coils.
• Test coils (Paragraph 60 or 65) and replace if inoperative.
Gas Models: Inoperative flame sensor.
• Test flame sensor (Paragraph 61 or 66) and replace if
inoperative.
Gas Models: Inoperative igniter.
• Test igniter (Paragraph 62 or 67) and replace if
inoperative.
Gas Models: Harness not properly connected to gas
controls.
• Check harness connections to gas valve coils, sensor and
main harness.
• Reconnect as required.
Gas Models: Restricted gas flow in gas orifice.
• Clean out gas orifice.
Some Gas Models: Tripped high limit thermostat.
• Reset thermostat.
Inoperative cycling thermostat.
• Test thermostat and replace if inoperative.
Inoperative timer.
• Test timer and replace if inoperative.
Broken, loose, or incorrect wiring.
• Refer to wiring diagram.