36
53273
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
40. TIMER CASE
a. Remove timer assembly. Refer to Paragraph
15, steps a through f.
b. Remove two control panel attaching screws and
lift assembly off panel support.
c. Remove cap screw, lockwashers and nut
holding timer case to control hood.
d. Remove two screws from bottom edge of front
panel. Pull bottom of panel away from dryer
until hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
e. Remove two cabinet top hold-down screws.
Refer to Figure 26.
f. Reinstall control panel on control hood.
g. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets.
NOTE: The cabinet top is self supporting.
h. Remove two carriage bolts, washers,
lockwashers and nuts holding front of timer
case to cabinet top.
i. Support timer case and remove screw holding
gasket and rear of case to cabinet top and
remove case.
41. CABINET TOP (Nonmetered Models)
a. Remove front panel. Refer to Paragraph 13.
b. Remove control panel. Refer to Paragraph 14,
step a or b.
c. Disconnect wires from all components and
ground wire in control hood. Push harness
through opening in cabinet top and replace
control panel or set aside to prevent damage.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
d. Remove two cabinet top hold-down screws.
Refer to Figure 26.
e. Lift front of cabinet top, disengage from hinges
from rear of cabinet. Refer to Figure 27.
f. Remove brace from under side of cabinet top by
swinging on end toward front or rear. Refer to
Figure 27.
g. Remove control hood and panel support (if
present) when replacing the cabinet top.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind unit while servicing the dryer.
Figure 25
DRY1219S
Timer Case
Attaching
Hardware
Figure 26
DRY856S
Cabinet Top
Hold-Down
Screw