53273
37
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
42. CABINET TOP (Metered Models)
a. Remove front panel. Refer to Paragraph 13.
b. Remove meter case. Refer to Paragraph 39.
c. Remove control pane. Refer to Paragraph 14,
step b and disconnect wires from all
components and ground wire in control hood.
Push harness through hole in control hood.
Refer to Figure 24.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
d. Remove two cabinet top hold-down screws.
Refer to Figure 26.
e. Lift front of cabinet top, disengage from hinges
on rear of cabinet. Refer to Figure 27.
f. Carefully withdraw wire harness through hole
in cabinet top and remove the top.
g. Remove brace from underside of cabinet top by
swinging one end toward front or rear. Refer to
Figure 27.
h. Remove control hood when replacing the
cabinet top. Refer to Paragraph 43.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind unit while servicing the dryer.
43. CONTROL HOOD
a. Remove control panel. Refer to Paragraph 14,
step a or b.
b. Remove or raise cabinet top. Refer to
c. Support control hood and remove four screws
holding control hood and gaskets to cabinet top.
d. Remove four screws holding panel support (if
present) to cabinet top.
44. FRONT AIR DUCT
Refer to Figure 28
a. Remove front panel. Refer to Paragraph 13.
b. Remove lint filter. Refer to Paragraph 30.
c. Remove two Phillips head and two hex head
screws holding air duct to front bulkhead and
lift off.
IMPORTANT: When reassembling be sure felt seal
on exhaust fan cover makes air tight seal on flange
of air duct. Refer to Figure 29.
Figure 27
DRY857S
Brace
Control Hood
Attaching
Screws
Cabinet Top
Hinges
Panel Support
Screws
(4)
Figure 28
DRY858S
Phillips Head
Screws
Air
Duct
Exhaust Duct
Attaching
Screw
Hex Head
Screws