53273
15
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 4
Service Procedures
IMPORTANT: When reference to direction (right
or left) is made in this manual, it is from the
operator’s position facing the front of the dryer.
IMPORTANT: Electrical test procedures in this
manual are performed by using a volt-ohm meter.
Tests can also be performed using a multimeter or
any other electrical testing equipment with which
the service person is familiar.
13. FRONT PANEL AND PANEL SEAL
Refer to Figure 1
a. Remove two screws from bottom edge of front
panel.
b. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top.
c. Disconnect wires from door switch.
NOTE: Refer to appropriate wiring diagram when
reconnecting switch.
d. Remove front panel seal from flange around
inside of door opening.
NOTE: Be sure seal is properly positioned when
installing on front panel.
Figure 1
DRY1214S
Guide
Lug
Hold-Down
Clip
Door
Switch
Front Panel
Seal
Striker
Catch
Access Door
(Gas Models)
Phillips Head
Screw
Door
Hinge
Hex Head
Screw
Locknut
Support Bracket
(Used through Serial
No. S70U4371)
Access Door Key
(Used through
Serial No. S840L627)