![Alliance Laundry Systems SE3930 Service Manual Download Page 29](http://html1.mh-extra.com/html/alliance-laundry-systems/se3930/se3930_service-manual_2901326029.webp)
53273
29
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
d. Sensor – Refer to Figure 12
NOTE: Sensor can be removed without removing
gas valve and bracket.
(1) Through Serial No. S840L627 – Insert
key into access door lock and turn one
quarter turn counterclockwise. Refer to
Figure 11.
Starting Serial No. S840L628 – Remove
Phillips head screw and washer holding
access door to front panel. Refer to
Figure 11.
(2) Apply thumb pressure to right edge of door.
When door opens, move door to the left to
disengage from door supports. Refer to
Figure 11.
(3) Remove wires from sensor terminals.
(4) Remove screw holding sensor to burner
housing.
e. Limit Thermostat – Refer to Figure 12
NOTE: Limit thermostat can be removed without
removing gas valve and bracket.
(1) Through Serial No. S840L627 – Insert
key into access door lock and turn one
quarter turn counterclockwise. Refer to
Figure 11.
Starting Serial No. S840L628 – Remove
Phillips head screw and washer holding
access door to front panel. Refer to
Figure 11.
(2) Apply thumb pressure to right edge of door.
When door opens, move door to the left to
disengage from door supports. Refer to
Figure 11.
(3) Remove wires from thermostat.
(4) Remove screws holding thermostat to
burner housing.
23. BURNER HOUSING
Refer to Figure 12
a. Remove front panel, Paragraph 13.
b. Remove gas valve and burner tube assemblies.
Refer to Paragraph 22, steps a and b.
c. Remove screw holding burner housing to heat
shroud and pull burner housing out through
front of dryer.
24. HEAT SHROUD
Refer to Figure 12
a. Remove front panel and burner housing. Refer
b. Remove screws holding shroud to heater box
and pull shroud out through front of dryer.
25. TERMINAL BLOCK OR POWER CORD
a. Terminal Block – Electric Models – Refer to
(1) Remove access plate on rear of cabinet.
(2) Remove all wires from terminal block.
NOTE: Refer to appropriate wiring diagram when
rewiring terminal block.
(3) Remove screws holding terminal lock to
bracket.
NOTE: Do not let terminal block shield drop when
removing the block. Shield must be in place when
reinstalling block.
Figure 15
DRY1215S
Terminal
Block
Terminal
Block
Screws
Ground
Wire
Access
Plate