![Alliance Laundry Systems SE3930 Service Manual Download Page 39](http://html1.mh-extra.com/html/alliance-laundry-systems/se3930/se3930_service-manual_2901326039.webp)
53273
39
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Test Drive Motor
Refer to Figure 30
1. Remove motor.
2. Disconnect wires from motor switch.
NOTE: Refer to appropriate wiring diagram when
rewiring motor switch.
3. Put test meter probes on terminals 4 and 5. Meter
should read approximately one ohm on ohm scale.
4. Put test meter probes on terminal 4 and motor
frame. Meter should register “no reading” or
infinite.
5. Put test meter probes on terminal 5 and motor
frame. Meter should register “no reading” or
infinite.
6. Put test meter probes on terminals 4 and 6. Meter
should register “no reading” or infinite. Manually
flex the centrifugal switch in motor and meter
should read approximately two ohms on ohm
scale.
7. Put test meter probes on terminals 1 and 2. Meter
should register “no reading”. Manually flex the
centrifugal switch in motor and meter should read
“zero ohms.
Figure 30
DRY838S
Motor
Switch
Drive
Motor