General Troubleshooting
6. Water Fill Does Not Stop At Proper Level
Water fill does not
stop at proper level.
Is pressure
switch
inoperative?
Test switch and
replace if
inoperative.
Yes
Is mixing
valve
inoperative?
Test valve and
replace if
inoperative.
Yes
Was there a siphoning
action started in washer
causing water to be
siphoned from washer
during cycle due to end
of drain hose being
lower than cabinet top of
washer?
Install 562P3
Siphon
Break Kit.
TLW329S
Yes
Is there
water in
pressure
hose?
Blow air
through hose to
remove water.
Yes
Is there
broken,
loose,
shorted or
incorrect
wiring?
Refer to
appropriate
wiring diagram.
No
Yes
Is there an
air leak in
pressure
hose?
Replace
hose.
Yes
No
Does drain
hose fit tight
in standpipe
or drain?
Provide an air
gap around
drain hose and
drain receptacle.
No
No
No
Yes
No