202202
43
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting (Electronic Control)
25. Washer Over Fills
With power
disconnected, does
the unit still over
flow?
Washer Over Fills.
Is there voltage
on either the orange
wire of the hot valve
or gray wire of the cold
valve to neutral?
Replace mixing
valve.
Check for
incorrect or
damaged wiring
between water
valve and L1
Yes
No
Yes
No
Reconnect
power.
(1)
Unit works
properly.
TLW2
8
7