L.P. Altitude Adjustments
Altitude
Orifice Size
Part No.
feet [m]
No.
inches
[mm]
3500 [1070]
54
0.0550 [1.40]
503785
7500 [2290]
55
0.0520 [1.32]
58755
11000 [3355]
56
0.0465 [1.18]
503786
Table 5
Electric Dryer Only - Connect Electrical
Plug
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 or 4
wire electrical supply. Refer to serial plate for specific electrical
requirements.
NOTE: The wiring diagram is located in the control
hood.
WARNING
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer’s responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.
W521
Earth/Ground Information
This appliance must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by
providing a path of least resistance for electric current. The cord-
kit must be equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if
you are in doubt as to whether the dryer is properly
grounded.
W038
Do not modify the plug provided with the cord-kit – if it will not
fit the outlet, have a proper outlet installed by a qualified electri-
cian.
The dryer has its own terminal block that must be connected to a
separate branch, 60 Hertz, single phase circuit, AC (alternating
current) circuit, fused at 30 Amperes (the circuit must be fused on
both sides of the line). Electrical service for the dryer should be
of maximum rated voltage (208 or 240 Volt, depending on heat-
ing element) listed on the serial plate. Do not connect dryer to
110, 115, or 120 Volt circuit.
Heating elements are available for field installation in dryers
which are to be connected to electrical service of different volt-
age than that listed on serial plate, such as 208 Volt.
NOTE: Branch circuit wire size requirements to laundry
room outlet are shown in table below.
Wire Length
Wire
Less than 15 ft. [4.5 m]
Listed No. 10 AWG Copper
wire only
Longer than 15 ft. [4.5 m]
Listed No. 8 AWG Copper
wire only
Table 6
The power cord connection between wall receptacle and dryer
terminal block IS NOT supplied with dryer. Type of power cord
and gauge of wire must conform to local codes.
IMPORTANT: Use only a new U.L. listed No. 10 (copper
wire only) three or four conductor power supply cord
kit rated 240 Volts (minimum) 30 Amperes and labled
as suitable for use in a clothes dryer.
Installation
24
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Part No. 512680R10