NOTE: On models with standard capacity meter case
and high capacity meter case models starting with Se-
rial Nos. beginning 1010: You have the option of using
a screw type lock or a 1/4 turn lock on the meter case
service door. If you choose to use a screw lock, then
the special bracket (located inside the meter case)
must be used. DO NOT use the special bracket if a 1/4
turn lock is used. High capacity meter case models
with Serial Nos. beginning 0910 through 1010 use 1/4
turn lock only.
Coin Drawer Security (Models with Standard Capacity Meter
Case and High Capacity Meter Case models starting with Serial
Nos. beginning 1010 Only) - For additional security, drill out the
two pilot holes on each side of the front of the meter case to holes
and install a bicycle lock through these holes.
Coin Slide Control
Power-Up Mode
When power is applied to the dryer, the control will enter the
Ready Mode. If the control was powered down during a running
a cycle, the IN USE LED will flash once and the control will en-
ter Start Mode. If the dry time dipswitch settings have not been
changed from factory default, the IN USE LED will flash once.
Ready Mode
In Ready Mode, the control waits for the vend to be satisfied be-
fore entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the Start button
has not been pressed. The IN USE LED will be lit. The timer will
not count down until the Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The IN USE LED is
lit.
Door Open Mode
In Door Open Mode, the control turns off the heater and motor
when the door is opened during a run cycle. The timer will con-
tinue to count down time and the IN USE LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the IN USE LED
is off. The control remains in this mode until the door is opened
or additional vend has been satisfied.
Top-Offs
Any time the control receives a coin slide pulse during a cycle it
will add the programmed dry time to the time currently remaining
in the cycle. The IN USE LED will flash briefly to indicate the
coin input. The maximum cycle time is 99 minutes. The control
will not add time beyond 99 minutes. The cool down time will
not change. If the control receives a coin slide pulse during cool
down it will exit cool down and start heating with the cycle time
equal to the programmed time.
Temperature Selector Switch
For five minutes after the control is powered up, there is a diag-
nostic feature that allows the temperature selector switches to be
tested. When the temperature selector is changed, the new setting
is displayed by flashing the IN USE LED as follows:
High/Normal
4 flashes
Medium/PP or Casual
3 flashes
Low/Delicate
2 flashes
No Heat
1 flash
Error Display Mode
The control enters Error Display Mode to display thermistor er-
rors. The heater is turned off, the IN USE LED flashes to indicate
the error (refer to paragraphs below), and the timer will continue
to count down time. The control remains in Error Display Mode
until the control senses the thermistor has returned to an accepta-
ble heating range, the cycle ends or machine is powered down.
Open Thermistor
If the control senses a temperature less than 0°F when the heat
has been on for at least three minutes it will set an open thermis-
tor error. The control will flash the IN USE LED twice separated
by a one and a half second pause. This sequence is repeated as
long as the Open Thermistor error is sensed.
Shorted Thermistor
If the control senses a temperature greater than 210 ± 4°F during
an active cycle it will set a Shorted Thermistor error. The control
will flash the IN USE LED three times separated by a one and a
half second pause. This sequence is repeated as long as the Short-
ed Thermistor error is sensed.
Setting Dry Time Dipswitches
To change the dry time on the dryer, combinations of dipswitches
can be set on the control. Refer to
Figure 34
.
Installation
Part No. 512680R10
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT