NOTE: The power cord is NOT supplied with the elec-
tric dryer. Type of power cord and gauge of wire must
conform to local codes and instructions. The method
of wiring the dryer is optional and subject to local code
requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the serial plate.
NOTE: Use COPPER WIRE only.
Shorter than 15 ft. (4.5 m) – use 10 AWG
Longer than 15 ft. (4.5 m) – use 8 AWG
D816I_SVG
L1 L2
L1 L2
15
16
5
2
2
3
4
8
9
12
13
10
11
7
6
1
14
1.
A typical 30-Amp Three-Wire Receptacle NEMA Type 10-30R
2.
120 ± 12 V.A.C.
3.
240 ± 12 V.A.C.
4.
Intermediate Fuse Box (may be omitted if service entrance box is fused)
5.
Wall Receptacle
6.
Power Supply
7.
3-Wire Earth/Ground Neutral 120/240 Volt, 60 Hertz AC 1 Phase Service Entrance Switch Box (Refer to NOTE above)
8.
30 Ampere Fuses or Circuit Breaker
9.
Neutral Wire
10.
Metallic or Non-Metallic Sheathed Cable (Copper Wire Only)
11.
Power Cord (Not supplied with dryer)
12.
Neutral
13.
Terminal Block in Dryer
14.
Intermediate Shut-Off Box (may or may not be fused)
15.
Direct Connection
16.
Power Cord Connection
Figure 12
1.
Disconnect power to dryer.
2.
Remove access cover from rear of dryer.
Installation
26
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Part No. 512680R10