Configuration Array
The embedded analog I/O configuration image array of the module contains 43
words as described in
.
Table 18 - CompactLogix 5370 L2 Controller Embedded Analog I/O Module Configuration Image Array
Word
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
Real Time Sample Value
1
ETS
Nu
2
EC
Nu
EA
AL
EI
EO
Open Circuit Ch0
0V Adj
Filter Setting ChI0
3
Wire & CLCD
TU ChIo
Nu
Inpt Dta Fm ChI0
Nu
Inpt Tp/RngeSel ChI0
4
S
Process Alarm High Data Value Universal Input Channel 0
5
S
Process Alarm Low Data Value Universal Input Channel 0
6
S
Alarm Dead Band Value Universal Input Channel 0
7
Nu
8
EC
Nu
EA
AL
EI
EO
Open Circuit ChI 1
0V Adj
Filter Setting ChI1
9
Nu
TU ChI1
Nu
Inpt Dta Fm ChI1
Nu
Inpt Tp/RngeSel ChI1
10
S
Process Alarm High Data Value Universal Input Channel 1
11
S
Process Alarm Low Data Value Universal Input Channel 1
12
S
Alarm Dead Band Value Universal Input Channel 1
13
Nu
14
EC
Nu
EA
AL
EI
EO
Open Circuit ChI 2
0V Adj
Filter Setting ChI2
15
Wire & CLCD
TU ChI1
Nu
Inpt Dta Fm ChI2
Nu
Inpt Tp/RngeSel ChI2
16
S
Process Alarm High Data Value Universal Input Channel 2
17
S
Process Alarm Low Data Value Universal Input Channel 2
18
S
Alarm Dead Band Value Universal Input Channel 2
19
Nu
20
EC
Nu
EA
AL
EI
EO
Open Circuit ChI 3
0V Adj
Filter Setting ChI3
21
Nu
TU ChI1
Nu
Inpt Dta Fm ChI3
Nu
Inpt Tp/RngeSel ChI3
22
S
Process Alarm High Data Value Universal Input Channel 3
23
S
Process Alarm Low Data Value Universal Input Channel 3
24
S
Alarm Dead Band Value Universal Input Channel 3
25
Nu
26
CJC Ses
Cycle
Calib
Nu
CJC WP
Nu
TU CJC
27
Nu
28
EC
NU
EHI
ELI
LC
ER
FM
PM
Nu
PFE
29
Nu
Outpt Fm ChI0
Nu
Outpt Tp/RngeSel Ch0
30
S
Fault Value Channel 0
31
S
Program (Idle) Value Channel 0
32
S
Clamp High Data Value Channel 0
33
S
Clamp Low Data Value Channel 0