Effective 11/1/07, Revised 1/1/09, Revised 8/1/09
49
Unique
PMO
Plus
®
Series Sanitary Mixproof Valve Instruction Manual
Maintenance
Note:
*
Lubricate seals with Kluber Paraliq GTE 703 or
similar USDA H1 Approved lubricant (#022148-213).
** Lubricate threads with Kluber Paste UH1 84-201 or
similar.
54
55
56
57
54
Re-Assemble Valve
(Excluding Actuator)
1. Hand clean and sanitize guide ring
(54).
2. Hand clean and sanitize ID of
upper plug stem (55).
3. Install guide ring
(54).
4. Install *lip seal
(57).
55
See pages 68 to 73 for part numbers.