Effective 11/1/07, Revised 1/1/09, Revised 8/1/09
9
Unique
PMO
Plus
®
Series Sanitary Mixproof Valve Instruction Manual
CV Values
Unique
PMO
Plus
®
-CP
1½"
2"
2½"
3"
4"
6"
Upper seat lift
1.7
2.6
3.9
3.9
5.3
12.1
Lower seat push
2.3
4.5
5.9
5.9
7.5
13.9
CIP solution flows for seat lift
(viscosity and density similar to water)
CV Values
Unique
PMO
Plus
®
1½"
2"
2½"
3"
4"
6"
Upper seat lift
1.7
2.6
3.9
3.9
5.3
12.1
Lower seat push
1.0
2.2
3.6
3.6
4.9
10.2
The following formula is used to estimate CIP low during seat lifts:
Q = Cv
(
√
∆
p
)
Where: Q = Flow in USGPM
Cv = Value from table above
∗ ∆
p = CIP pressure in PSI
CIP solution flows for seat lift
(viscosity and density similar to water)
The following formula is used to estimate CIP low during seat lifts:
Q = Cv
(
√
∆
p
)
Where: Q = Flow in USGPM
Cv = Value from table above
∗ ∆
p = CIP pressure in PSI
Speciications