7.4.3
Oil discharge through water
outlet = broken water seal
Possible cause
Action
Gravity disc too large.
Use a gravity disc with a smaller hole.
Separation temperature too low.
Increase temperature.
Throughput too high.
Reduce throughput.
The supply of operating water is not
sufficient due to clogged strainer, kinked
hose or low water pressure.
Straighten the hose. Clean the strainer. Check the
water pressure.
Valve(s) in oil outlet line closed.
Open the valve(s) and adjust the back pressure to
normal value.
Sealing water volume too small.
Check water supply.
Disc stack clogged.
Clean the bowl discs.
Seal ring on gravity disc/clarifier disc
defective.
Fit a new seal ring.
Seal ring in sliding bowl bottom or upper
or lower distribution ring defective.
Install a new seal ring.
Bowl hood seal ring defective or sealing
surface of sliding bowl bottom damaged.
Install a new seal ring. Polish the surface on sliding
bowl bottom or install a new one.
Valve plugs defective.
Install new valve plugs on operating slide.
Bowl speed too low.
See ‘‘7.2.10 Speed too low” on page 131.
Bowl incorrectly assembled.
Examine and make correct.
www.fdm.com.pe
Summary of Contents for MMPX 303SGP-11
Page 6: ...ventas fdm com pe fdmsac gmail com Movil 959440045 6 www fdm com pe...
Page 14: ...ventas fdm com pe fdmsac gmail com Movil 959440045 2 Safety Instructions 14 www fdm com pe...
Page 78: ...ventas fdm com pe fdmsac gmail com Movil 959440045 78 www fdm com pe...
Page 124: ...ventas fdm com pe fdmsac gmail com Movil 959440045 124 www fdm com pe...
Page 155: ...ventas fdm com pe fdmsac gmail com Movil 959440045 155 www fdm com pe...
Page 159: ...ventas fdm com pe fdmsac gmail com Movil 959440045 159 www fdm com pe...
Page 174: ...ventas fdm com pe fdmsac gmail com Movil 959440045 174 www fdm com pe...
Page 176: ...ventas fdm com pe fdmsac gmail com Movil 959440045 176 www fdm com pe...
Page 178: ...ventas fdm com pe fdmsac gmail com Movil 959440045 178 www fdm com pe...