7.3
Purification and
clarification faults
7.3.1
Liquid flows through bowl
casing drain and/or sludge
outlet
Possible cause
Action
Sludge discharge or water draining in
progress.
None (normal).
Broken water seal.
See ‘‘7.4.3 Oil discharge through water outlet =
broken water seal” on page 135.
Displacement water volume too large.
Adjust.
The supply of operating water is not
sufficient due to clogged strainer, kinked
hose or low water pressure.
Straighten the hose. Clean the strainer. Check the
water pressure.
Seal ring on gravity disc/clarifier disc
defective.
Fit a new seal ring.
Seal ring in sliding bowl bottom defective.
Install a new seal ring.
Bowl hood seal ring defective or sealing
surface of sliding bowl bottom damaged.
Install a new seal ring. Polish the surface on sliding
bowl bottom or install a new one.
Valve plugs defective.
Install new valve plugs.
Sludge deposits on operating slide.
Clean the operating slide.
Seal rings in paring disc device defective.
Fit new seal rings.
Bowl speed too low.
Make sure current is on. Retighten the flat belt or
inspect motor and power transmission.
www.fdm.com.pe
Summary of Contents for MMPX 303SGP-11
Page 6: ...ventas fdm com pe fdmsac gmail com Movil 959440045 6 www fdm com pe...
Page 14: ...ventas fdm com pe fdmsac gmail com Movil 959440045 2 Safety Instructions 14 www fdm com pe...
Page 78: ...ventas fdm com pe fdmsac gmail com Movil 959440045 78 www fdm com pe...
Page 124: ...ventas fdm com pe fdmsac gmail com Movil 959440045 124 www fdm com pe...
Page 155: ...ventas fdm com pe fdmsac gmail com Movil 959440045 155 www fdm com pe...
Page 159: ...ventas fdm com pe fdmsac gmail com Movil 959440045 159 www fdm com pe...
Page 174: ...ventas fdm com pe fdmsac gmail com Movil 959440045 174 www fdm com pe...
Page 176: ...ventas fdm com pe fdmsac gmail com Movil 959440045 176 www fdm com pe...
Page 178: ...ventas fdm com pe fdmsac gmail com Movil 959440045 178 www fdm com pe...