6.7 Regasketing
NOTE
For Front 15, you must perform actions in addition to the instructions
below to make the gaskets seal properly. Contact your Alfa Laval
representative for advice.
The procedures below concern field gaskets, ring gaskets and end gaskets.
NOTE
Before removing the old gaskets, check how they are attached.
6.7.1 Clip-on / ClipGrip
1
Open the plate heat exchanger, refer to
NOTE
Before opening the plate heat exchanger,
check the warranty conditions. If in any
doubt, contact the Alfa Laval sales
representative. See Section
in Chapter
2
Remove the old gasket with the plate still
hanging in the frame.
3
Make sure that all sealing surfaces are dry,
clean and free of foreign matter such as fat,
grease or similar.
4
Check the gasket and remove rubber residual
before attaching it.
NOTE
Especially the end plate gasket!