6.4 Manual cleaning of opened units
CAUTION
Never use hydrochloric acid with stainless steel plates. Water of more
than 330 ppm Cl may not be used in the preparation of cleaning solutions.
It is very important that aluminium carrying bars and support columns are
protected against chemicals.
NOTE
Be careful not to damage the gasket during manual cleaning.
WARNING
Risk of personal injury.
Use proper personal protective equipment when using the cleaning
agents. See Section
.
WARNING
Risk of personal injury.
Corrosive cleaning liquids. Can cause serious injuries to skin and eyes.
Use proper personal protective equipment when using the cleaning
agents. See Section
.
6.4.1 Deposits removable with water and brush
Plates do not need to be removed from the plate heat exchanger during cleaning.
WARNING
Risk of personal injury.
Consider risks such as loose particles and the kind of media that has been used in the plate heat
exchanger.
Use proper personal protective equipment. See Section
1
Start cleaning when the heating surface is still
wet and the plates are hanging in the frame.
2
Remove deposits using a soft brush and
running water.
200000420-4-EN-GB
59
Maintenance 6
EN