Seal fitting
NOTE
Ensure all screws and nuts are torqued to the
values stated in Section 6.
3206-0075
Model
Dimension X (mm)
32/33/34
5.5
42/43
8
52/53/54
6.5
62/63
9
72/73/74
9.5
x
3206-0046
3
1.
If the static assembly (105) was removed,
align the line mark on front face of with
the lugs in the bore of the rotorcase (2)
and press back ensuring the drive ring is
kept square to the bore until fully
engaged.
2.
Ensure the static assembly is fully seated
by checking dimension shown below
against the table. If not remove the static
assembly, refit and check.
3.
Lubricate the squad ring (104) and fit to
the static seal face (103) ensuring the lip
of the elastomer is towards the seal face
(larger diameter) as shown in the
diagram. Note: the coloured mark should
be facing away from the static seal face.
4.
Align the slots in the static seal face (103)
with the pins in the static assembly (105)
and press back gently until fully engaged.
5.
Wipe clean the stationary seal faces with
solvent.
3206-0043
104
103
3206-0044