Flushing fluid.
The choice of flushing fluid is
dependent upon the fluid being pumped and
duty conditions i.e. pressure and
temperature. Usually water is used for cooling
or flushing water-soluble products. For both
single flushed and double mechanical seal
arrangements the temperature of the flush
media should never be allowed to exceed the
maximum temperature of the pumped media.
For advice on selecting a suitable flushing
fluid please contact pump supplier.
4
Flush Pressure & Flow Limits:
Single Mechanical Flushed - 0.5 bar max
Double Seal (SiC/Carbon) - 1 bar above
pump discharge upto 16 bar max
Double Seal (SiC/SiC) - 1 bar above pump
discharge upto 20 bar max
O-Ring Seal Flushed - 0.5 bar max
Flush Media Flow (all seal types) - 30 l/h per
seal minimum
5
Pre-start up checks
• Check the pipework system has been
purged to remove debris.
• Check all obstructions have been removed
from pipework and pump.
• Check pump connections and pipework
joints are tight.
• Check lubrication levels are correct.
• Check seal flushing is connected if
applicable.
• Check all safety guards are in place.
• Check that inlet and outlet valves are
open.