15
2
Maintenance Directions
2.1
Periodic maintenance
2.1.1
Introduction
Periodic (preventive) maintenance reduces the
risk of unexpected stoppages and breakdowns.
Follow the maintenance logs on the following
pages in order to facilitate the periodic
maintenance.
2.1.2
Maintenance intervals
The following directions for periodic maintenance
give a brief description of which parts to be
cleaned, checked and renewed at different
maintenance intervals.
The maintenance logs for each maintenance
interval later in this chapter give detailed
enumeration of the check points that must be
done.
Daily checks consist of minor check points to
carry out for detecting abnormal operating
conditions.
Oil change
The oil change interval is every 1000-1500 hours
or at least once every year if the total number of
operating hours is less than 1000-1500 hours.
DANGER
Disintegration hazards
Separator parts that are either worn beyond
their safe limits or incorrectly assembled may
cause severe damage or fatal injury.
Summary of Contents for AFPX 617XGV-14/74CG
Page 1: ...0 5 0 0 E 0 DVcgZTV RZ_eV_R_TV R_fR DVaRcRe c 27AI I8G 48 a SdRc 1 Z ATe...
Page 6: ...6...
Page 8: ...8...
Page 14: ...1 Safety Instructions 14...
Page 46: ...2 7 Common maintenance directions 2 Maintenance Directions 46...
Page 103: ...103 3 Dismantling Assembly 3 5 Major Service MS dismantling...
Page 148: ...148...
Page 150: ...150...
Page 154: ...154...