3.8 Operating water module compact (OWMC)
3 Dismantling/Assembly
144
3.8.2
Dismantling (MS service)
The figures within brackets refer to the exploded
view on page
When dismantling, the OWMC Service kit is
needed.
1.
Shut off the air and operating water supply to
the OWMC.
2.
Remove the connections for operating water.
3.
Turn the cylinder (2) anti-clockwise relative to
the air tank (16). The upper locking wire is
thereby forced out.
Use two belt wrenches when turning the
cylinder, see the illustration. The lower tool
prevents the air tank from rotating.
DANGER
Crush hazard
Never dismantle the OWMC when
pressurized.
NOTE
The Air tank (16) must only be dismantled by
Alfa Laval personel.
NOTE
Be careful to keep the cylinder straight
against the air tank.
NOTE
In order not to damage the water tank, make
sure to place the upper wrench at the top of
the water tank, as illustrated.
G
0
87
81
31