27/33
ALFA IN a.s. ©
www.alfain.eu
3. The left display
V10
shows the set value of the welding current, the right
display
V11
shows the abbreviation ELE.
4. Set the value of the welding current using encoder
V5
.
5. During welding, the welding current is measured on display
V10
and the
voltage on display
V11
.
6. After the welding is finished, the measured value (
HOLD
) remains on the
display for 6 s.
7. If a Torch with a remote control is connected, ELE is shown on its display
.
8.
If the MIG/MAG torch remains connected, the welding voltage will be
on it!
12 CONSUMPTION TABLES
TABLE OF WIRE CONSUMPTION DURING WELDING
Wire
diameter
[mm]
Wire feed
speed
range
[m/min]
Maximum
wire feed
speed
[m/min]
Weight of
1 m wire
[g]
Wire consumption
per 1 minute of
welding
[g/min]
Wire
consumption per
1 hour of welding
[
g/hr]
Steel wire
0,6
2 - 5
5
2,3
11,5
690
0,8
3 - 6
6
4
24
1440
1,0
3 - 12
12
6
72
4320
1,2
4 -18
18
9
162
9720
Stainless steel wire
0,6
2 - 5
5
2,3
11,5
690
0,8
3 - 6
6
4
24
1440
1,0
3 - 12
12
6
72
4320
1,2
4 -18
18
9
162
9720
Aluminium wire
0,6
2 - 5
5
0,8
4
240
0,8
3 - 6
6
1,3
7,8
468
1,0
3 - 12
12
2
24
1440
1,2
4 -18
18
3
54
3240
TABLE OF GAS CONSUMPTION DURING WELDING
Wire diameter [mm]
Gas flow [l/min]
Gas consumption per 1 hour
of welding [l/hour]
0,6
6
6 * 60 = 360
0,8
8
8 * 60 = 480
1,0
10
10 * 60 = 600
1,2
12
12 * 60 = 720