25/33
ALFA IN a.s. ©
www.alfain.eu
9
PULSE MODE
1. Press the
V2
button to switch on the pulse mode (only available for
specified synergy programs).
2. Switching on the pulse mode is indicated by LED
V3
at the
V2
button.
3. The left display
V10
shows the machine power (current, wire feed speed,
material thickness), the right display
V11 shows the
voltage value. The
correction value (voltage, wire feed speed) is shown on the
V11
display
only during setup.
4. Press the
V8
button to switch the settings and display the machine
performance (current, wire feed speed, material thickness).
5. Set the machine output (current, wire feed speed, material thickness) using
the
V5
encoder.
6. The calibration menu can be set to disable the resetting of the correction
when the machine power value changes.
7. Long press the
V13
button to switch the wire tension and feed rate
correction.
8. Adjust the voltage or wire feed rate correction using encoder
V16
(if
necessary).
9. Press the
V20
button to switch between
2T/4T/2T-stairs/4T-stairs
mode.
10.
If a torch with remote control is connected, its display shows machine
power (current, wire feed speed, material thickness), correction (voltage,
wire feed speed), choke value or JOB. Use the
UP/DOWN
buttons to
adjust the displayed value,
use the MODE button
to switch between
functions.
10 WELDING MIG/MAG MANUAL
1. Select the
MAN
method according to SELECTION OF THE WELDING
METHOD.
2. The left display
V10
shows the wire feed rate, the right display
V11 shows
the
voltage or choke.
3. Set the wire feed speed using encoder
V5
.
4. Set the voltage or inductor using the
V16
encoder.
5. Select the setting and display of the voltage or choke by long pressing the
V13
button.
6. Press the
V20
button to switch between
2T/4T
modes.
7. During the welding process, the welding current is displayed on
V10
and
the voltage is displayed on
V11
.