13. RESET
The reset procedure involves complete restoration of the default values,
parameters and memory settings set in the factory.
All memory locations will be reset and hence all your personal welding
settings will be lost!
The reset procedure is useful in the following cases:
1. too many changes made to the welding parameters so user finds it
difficult to restore defaults.
2. unidentified software problems that prevent the welding power source
from functioning correctly.
Set the welding power source ON/OFF switch to “O” to switch the unit off.
Set the welding power source ON/OFF switch to “I” to switch on the unit.
P11
and
P26
; Hold down both buttons simultaneously. Perform this
operation before the message “SYNCHRONIZATION“ appears on the
following display:
P25
.
FACTORY SETUP MEMORY CLEANING
The message appears on the following displays:
P25
P11
and
P26
Release buttons.
Wait for the memory clear procedure to terminate.
The unit restarts with the power-up procedure.
14. ROUTINE MAINTANCE & INSPECTION
1. The only routine maintenance required for the aXe range of machines is
a thorough cleaning and inspection, with the frequency depending on
the usage and the operating environment.
WARNING
Disconnect the aXe from the mains supply voltage before disassembling.
Special maintenance is not necessary for the control unit parts in the Welder.
If these parts are damaged for any reason, replacement is recommended.
CAUTION
2. Do not blow air into the welder during cleaning. Blowing air into the
welder can cause metal particles to interfere with sensitive electronic
components and cause damage to the welder.
3. To clean the welder, disconnect it from the mains supply voltage then
open the enclosure and use a vacuum cleaner to remove any