IPUP A100 technical characteristics
Characteristics
UNITS
A100L
(1)
A100LI
(1)
A100P
(1)
A100PI
(1)
v
Rotation speed
Hz
rpm
100
6000
100
6000
100
6000
100
6000
v
Peak Pumping speed
m
3
/h
l/min
cfm
95
1583
63
95
1583
63
95
1593
63
95
1593
63
v
Ultimate pressure (without N
2
purge)
v
Ultimate pressure (with 30 slm
N
2
purge)
mbar
mTorr
mbar
mTorr
1.2.10
---2
9
1.2.10
---2
9
1.2.10
---2
9
6.10
---2
50
1.2.10
---2
9
6.10
---2
50
v
Max. continuous inlet pressure
Torr
50
50
50
50
v
Supply voltage 3PH
V
200 -- 208 V -- 3 phase -- 50/60Hz
(3)
v
Maximum continuous power
(at max. pressure)
kW
2.5
v
Power consumption at ultimate
pressure
kW
1.8
1.8
2.05
2.05
v
Average sound level at full
speed
dbA
55
50
55
50
speed
v
Guaranted sound level at full
speed
dbA
58
---
58
---
v
N
2
Flowrate range
slm
--
min. 20/ max. 50
v
Ambient temperature
° C
15 to 50
15 to 50
v
Water flow
l/h
min. 100
v
Water temperature
° C
min. 10 / max. 25
v
Gear box fluid capacity
(2)
cm
3
cc
150
v
Weight (without hand held
display module)
lbs/Kg
220.4 / 100
v
Inlet flange
DN 50 iso KF
v
Exhaust flange
DN 25 iso KF
v
Secondary exhaust port
DN 25 iso KF
v
Interstage flange
DN 25 iso KF
v
Max exhaust flow
cfm
13
---
13
---
Vibration level at the enclosure
baseplate sidehole (4 to 400 Hz
Spectrum)
v
Acceleration
v
Displacement
v
Speed
G
µ
m
mm/s
<
0.1
<
1.5
<
1
(1)
Variable speed control, min. 20 Hz / max. 100 Hz.
(2)
Oil charge is filled at factory. Do not modify the oil level.
(3)
According to CE regulations, IPUP A100 can withstand a supply voltage variation of
¦
10%.
G
B
00
51
8