A 20
2 / 3
Alcatel Vacuum Technology France --- IPUP A100 Instruction manual
IPUP A100 description
INTERNAL EQUIPMENT OF THE
IPUP A100 PUMPS
IPUP A100P/PI equipment
The IPUP A100P/PI is designed for corrosive processes, so it is
equipped with:
l
nitrogen injection and water cooling circuit optimized to avoid
deposition and condensation,
l
temperature regulation device.
The IPUP A100PI pump is equipped with an additional intermediate port
for specific applications where a permanent pumping flow of about
35 m
3
/h is required (example: dynamic seal pumping).
P
IPUP A100P/PI EQUIPMENT
Pump
¡
Low pressure stage
©¢£
Transfer stages
¤
High pressure stage
INLET
EXHAUST
Tc
M
2
1
3
4
5
6
9
9
7
Monitoring
Pump
Motor
Frequency converter
Anti suckback valve
Inert gas
Water IN
SILENCER
Supply block
Gas circuit
¥
Gas solenoid valve
¦
Pressure regulator
§
Inert gas purge nozzles
Cooling circuit
¨
Water solenoid valve
Sensors
Tc Temperature sensor
P Pressure sensor
M Motor sensor
Water OUT
8
8
Intermediate port for IPUP A100PI version only
Tc
8
8
8
G
B
00
51
6