For horizontal or vertical IDU installation the mechanical support must be fixed using the expansion anchors
supplied with the mechanical support.
Install the mechanical support (see Figure 65 on page 69) following the steps listed below:
460 mm
100 mm
WALL KIT INSTALLATION
(REAR VIEW)
500 mm
200 mm
300 mm
Ø 10 mm
Figure 65 - Fixing the mechanical support to the wall (horizontal and vertical)
(1) Locate the position on the wall.
(2) Mark the holes to be drilled on the wall.
(3) Temporarily remove the support and drill the holes at the points drawn on the wall.
(4) Place the inserts into the holes.
(5) Anchor the mechanical support to wall without tightening the bolts.
(6) Check the support’s perpendicularity using a spirit level or a plumb bob.
(7) Fix the mechanical support using expansion bolts.
Operator electrostatic coiled cord