SF/CPM LEDs
Page 116
7750 SR-12
Power Supply
1,2,3,4
Power Supply LEDs are lit only on the active CPM.
• Green: Indicates that a power supply module is installed and
operational in the associated slot.
• Amber: Indicates an error condition with an installed power supply
module in the associated slot.
• Unlit: Indicates that a power supply module is not installed or not
recognized.
If AC power rectifiers are used, then a status cable must be connected
from each AC power shelf to a DC PEM in order for status to be
monitored.
• LED 1: Displays status for DC PEM A.
• LED 2: Displays status for DC PEM B.
• LED 3: Displays status for AC power supply shelf 1.
• LED 4: Displays status for AC power supply shelf 2.
Fan Status
1,2,3
Fan Status LEDs are lit only on the active CPM.
• Green: Indicates that a cooling tray is installed and operational.
• Amber: Indicates a cooling tray failure.
• Unlit: Indicates that a cooling tray is not installed.
Compact Flash
1,2,3
Compact Flash LEDs are lit on both the active and standby CPMs.
• Green: Indicates that the flash card is operational and in a read or write
process.
Note: Do not remove the flash card when the LED is lit green.
• Amber (solid): Error condition exists.
• Amber (blinking): Indicates that the slot is in an operationally down
mode. This is the only mode to safely remove the flash card.
• Unlit: A flash card is not installed in the slot.
Alarms
The Alarm LEDs are lit only on the active CPM.
OT
Red: An overtemperature condition exists.
If there are no OT conditions, this LED should remain off.
Crit
Red: A critical condition exists, such as a severe overtemperature
condition, a fan tray failure, an overcurrent condition in a power supply,
or an out-of-tolerance voltage.
If there are no critical conditions, this LED should remain off.
Maj
Red: A serious condition exists, such as an overtemperature condition, a
fan tray failure, an overcurrent condition in a power supply, or an out-of-
tolerance voltage.
If there are no major conditions, this LED should remain off.
Table 30: Model SFM-400G SF/CPM Field Descriptions (Continued)
Key
Label/Part
Sub-
category
Description
Summary of Contents for 7750 SR-12
Page 1: ...7750 SR 12 INSTALLATION GUIDE Document Part Number 93 0019 01 December 2003 ...
Page 6: ...Page 4 7750 SR 12 Table of Contents ...
Page 14: ...Page 12 7750 SR 12 ...
Page 84: ...Monitoring AC Power Page 82 7750 SR 12 ...
Page 100: ...Establishing Router Connections Page 98 7750 SR 12 ...
Page 150: ...Impeller Trays Page 148 7750 SR 12 ...