/ Swimming Pool Heat Pump Inverboost C
Regulation (EU) n° 517/2014 of 16/04/14 on fluorinated greenhouse gases and repealing Regulation
(EC) n° 842/2006
Leak checks
1. Operators of equipment that contains fluorinated greenhouses gases in quantities of 5 tons of CO
2
,
equivalent or more and not contained in foams shall ensure that the equipment is checked for leaks.
2. For equipment that contains fluorinated greenhouse gases in quantities of 5 tons of CO
2
equivalent
or more, but of less than 50 tons of CO
2
equivalent: at least every 12 months.
Picture of the equivalence CO
2
1. . Load in kg and Tons amounting CO
2
.
Concerning the Gas R32, 7.40kg amounting at 5 tons of CO
2
, commitment to check each year.
Training and certification
1. The operator of the relevant application shall ensure that the relevant personnel have obtained
the necessary certification, which implies appropriate knowledge of the applicable regulations
and standards as well as the necessary competence in emission prevention and recovery of
fluorinated greenhouse gases and handling safety the relevant type and size of equipment.
Record keeping
1. Operators of equipment which is required to be checked for leaks, shall establish and maintain
records for each piece of such equipment specifying the following information:
a) The quantity and type of fluorinated greenhouse gases installed;
b) The quantities of fluorinated greenhouse gases added during installation, maintenance or
servicing or due to leakage;
c) Whether the quantities of installed fluorinated greenhouse gases have been recycled or
reclaimed, including the name and address of the recycling or reclamation facility and, where
applicable, the certificate number;
d) The quantity of fluorinated greenhouse gases recovered
e) The identity of the undertaking which installed, serviced, maintained and where applicable
repaired or decommissioned the equipment, including, where applicable, the number of its
certificate;
f)
The dates and results of the checks carried out;
g) If the equipment was decommissioned, the measures taken to recover and dispose of the
fluorinated greenhouse gases.
2. The operator shall keep the records for at least five years, undertakings carrying out the activities
for operators shall keep copies of the records for at least five years.
Do no release R32 coolant liquid into the atmosphere. This is a fluoride greenhouse effect
gas covered by the Kyoto agreement with a global warming potential (GWP) = 675 - (see
the European Community regulations on fluoride greenhouse effect gases Regulation (EU)
No 517/2014).
Load and Tons amounting CO
2
Frequency of test
From 7 at 75 kg load = from 5 at 50 Tons
Each year