Initial operation
7.
7.1. Initial operation
Note: In order to heat the water in the pool (or hot tub), the filter pump must be running to cause
the water to circulate through the heat pump. The heat pump will not start up if the water is not
circulating.
After all connections have been made and checked, carry out the following procedure:
1. Switch on the filtration pump. Check for leaks and verify that water is flowing from and to the
swimming pool.
2. Connect power to the heat pump and press the On/Off button on the electronic control panel.
The unit will start up after the time delay expires (see below).
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filtration pump, the unit should also turn off automatically, if not, then adjust the
flow switch.
5. Allow the heat pump and the filter pump to run 24 hours a day until the desired water temperature is
reached. The heat pump will stop running at this point +1°C. After this, it will restart automatically
(as long as the filtration pump is running) whenever the swimming pool water temperature drops
1 degree below the set temperature (for example, if you set the temperature 28°C, the heat pump
will stop when the temperature at 29°C. While it will restart when the temperature of the water
down to 27°C)
Depending on the initial temperature of the water in the swimming pool and the air temperature, it
may take several days to heat the water to the desired temperature. A good swimming pool cover can
dramatically reduce the required length of time.
1 m above or below the heat pump’s automatic adjustment knob, your dealer may need to adjust its
initial startup.
Time delay -
The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid
excessive contact wear. The unit will restart automatically after this time delay expires. Even a brief
power interruption will trigger this time delay and prevent the unit from restarting immediately.
Additional power interruptions during this delay period do not affect the 3-minute duration of the
delay.
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water
flow rate. It will turn on when the filtration pump runs and shut it off when the pump shuts
off. If the pool water level higher than 1 m above or below the heat pump’s automatic
adjustment knob, your dealer may need to adjust its initial startup.
NOTE