Swimming Pool Heat Pump Inverboost C  / 

 

29

8.2.   

Other Malfunctions and Solutions (No display on LED wire 
controller)

Malfunctions

Observing

Reasons

Solution

Heat pump is 
not running

LED wire 
controller no 
display.

No power supply

Check cable and circuit breaker if 
it is connected

LED wire 
controller. 
Displays the actual 
time. 

Heat pump under 
standby status

Startup heat pump to run.

LED wire 
controller displays 
the actual water 
temperature.

1.  Water temperature 

is reaching to setting 
value, HP under 
constant temperature 
status.

2.  Heat pump just starts 

to run.

3.  Under defrosting.

1.  Verify water temperature 

setting.

2.  Startup heat pump after a few 

minutes.

3.  LED wire controller should 

display „Defrosting“.

Water 
temperature is 
cooling when 
HP runs under 
heating mode

LED wire 
controller displays 
actual water 
temperature and 
no error code 
displays.

1.  Choose the wrong 

mode.

2.  Figures show defects.
3.  Controller defect.

1.  Adjust the mode to proper 

running 

2.  Replace the defect LED wire 

controller, and then check 
the status after changing 
the running mode, verifying 
the water inlet and outlet 
temperature.

3.  Replace or repair the heat 

pump unit

Short running

LED displays 
actual water 
temperature, 
no error code 
displays.

1.  Fan NO running.
2.  Air Fan is not enough.
3.  Refrigerant is not 

enough.

1.  Check the cable connections 

between the motor and fan, 
if necessary, it should be 
replaced.

2.  Check the location of heat 

pump unit, and eliminate all 
obstacles to make good air 
Fan.

3  Replace or repair the heat 

pump unit.

Water stains

Water stains on 
heat pump unit.

1.   Concreting.
2.  Water leakage.

1.  No action.
2.  Check the titanium heat 

exchanger carefully if it is any 
defect.

Too much ice on 
evaporator

Too much ice on 
evaporator.

1.  Check the location of heat 

pump unit, and eliminate all 
obstacles to make good air 
Fan.

2.  Replace or repair the heat 

pump unit.

Summary of Contents for Inverboost C

Page 1: ...Swimming Pool Heat Pump Inverboost C VERZE 17 01 2020 17 01 2020 EN INSTALLATION AND USER GUIDE...

Page 2: ...ach piece of such equipment specifying the following information a The quantity and type of fluorinated greenhouse gases installed b The quantities of fluorinated greenhouse gases added during install...

Page 3: ...l be damaged because of being frozen in such case your warranty will be lost 4 Please always cut the power supply if you want to open the cabinet to reach inside the heat pump 5 Please keep the displa...

Page 4: ...Included with your Heat Pump Water connection assembly 50 mm pcs 2 User and service manual Drain connection qty 2 Drain hose qty 2 10 meters signal wire Waterproof box Anti vibration base pcs 4 1 2 D...

Page 5: ...Swimming Pool Heat Pump Inverboost C 5 XHPFDPLUS160E...

Page 6: ...and no fire source Heat pumps must be stored and transferred in vertical position in its original packaging If it is not the case it cannot be operated until a minimum period of 24H has passed before...

Page 7: ...P 7 1 4 6 7 2 4 6 General data Compressor type MITSUBISHI MITSUBISHI Voltage V 220 240V 50Hz or 60Hz 1PH Rated current A 6 9 11 8 Minimum fuse A 10 18 Advised pool volume with pool cover m 12 33 25 8...

Page 8: ...tool for the optimization of the heating of the water The valves allows the optimum flow of water using a manometer to make sure the optimized running of the compressor see paragraph 5 6 controls of t...

Page 9: ...t the cables in the correct terminal according to electric diagram Filtration pump wiring Dry contact 1 Open the top cover of the heat pump 2 Connect the cables in the correct terminal according to el...

Page 10: ...imum distance of the pump from the pool circulation pump is 7 5 metres Location and connection 5 ATTENTION Please observe the following rules when installing the heat pump 1 Any addition of chemicals...

Page 11: ...sort must always be fitted in the piping on the downstream side of the heat pump and it is recommended to install a check valve to prevent reverse flow in the absence of water circulation Damage to t...

Page 12: ...pplies only the heat pump All other components including a bypass if necessary must be provided by the user or the installer NOTE Item Product description 1 Heat pump 2 Water processor 3 Side connecti...

Page 13: ...W V U JTAG RED RED I1 I2 OUT9 NO COM OUT6 OUT5 OUT4 N6 N5 N4 N2 N3 OUT3 N9 N1 OUT2 OUT1 COM OUT10 1 2 NO NO 3 TH1 TH2 TH5 TH4 TH3 TH8 TH7 TH6 NOTE 1 Above electrical wiring diagram only for your refe...

Page 14: ...le This section is indicative and should be checked and adapted according to the needs and conditions of use The tolerance of acceptable voltage variation is 10 during operation The connections must b...

Page 15: ...ops 1 degree below the set temperature for example if you set the temperature 28 C the heat pump will stop when the temperature at 29 C While it will restart when the temperature of the water down to...

Page 16: ...mal value of the gas pressure R32 when the machine is in power off or running conditions The amount of condensation may be as much as several litres per hour at high relative humidity The condensate w...

Page 17: ...to stop the heat pump unit and show OFF Notice During the parameter checking and setting press the to quick exit and save the current setting Press again to turn on off the machine 7 4 2 button Autom...

Page 18: ...18 Swimming Pool Heat Pump Inverboost C Operation logic of Auto Mode Auto Mode Heating mode Logic of auto mode Heating Standby Heating Heating Cooling Standby Standby Tset 28 C...

Page 19: ...Code Condition Scope Remark d0 IPM mould temperature 0 120 C Real testing value d1 Inlet water temp 9 C 99 C Real testing value d2 Outlet water temp 9 C 99 C Real testing value d3 Ambient temp 30 C 70...

Page 20: ...when it is in operation 7 4 8 Symbol of automatic start the light will be on when it is in operation 7 4 9 Press this button the light will be flash the heat pump will operate in Full output only 7 4...

Page 21: ...ted Condition to stop the heat pump timer OFF actives Before the TIMER OFF the heat pump stops and the filtration is still activated When timer reaches the set time of the TIMER OFF the heat pump will...

Page 22: ...rotection Mode Output water temperature Set Point temperature Condition Malfunction Heating mode 36 C 29 C Tout Tset 7 C EE04 Overheating protection for water temperature T2 Cooling mode 23 C 30 C Tse...

Page 23: ...uit 2 The wiring of sensor is loose 1 Check or change the sensor 2 Re fix the wiring of the sensors Exhaust piping sensor failure d6 TH3 PP06 1 The sensor in open or short circuit 2 The wiring of sens...

Page 24: ...s blocked or pipe system is jammed 2 Fan motor speed is abnormal or fan motor is damaged under heating mode 3 Gas leakage 4 Low pressure wire is loose or damaged 1 Check the EEV and piping system Chec...

Page 25: ...nection for compressor phase sequence 3 Compressor accumulations of liquid and oil lead to the current becomes larger 4 Compressor or driver board damaged 5 The water flow is abnormal 6 Power fluctuat...

Page 26: ...Check if the power is in the normal range 2 Change driver board Input current over high protection EE13 1 The compressor current is too large momentary 2 The water flow is abnormal 3 Power fluctuatio...

Page 27: ...s any barrier in front of fan blade and remove it PFC module thermal circuit is abnormal EE18 The driver board is damaged 1 Check if the motor speed is too low or fan motor is damaged replace it by a...

Page 28: ...oard EE24 Ambient Temperature device failure Change driver board or main board Compressor phase failure EE25 Compressors U V W are just connected to one phase or two phases Check the actual wiring acc...

Page 29: ...d no error code displays 1 Choose the wrong mode 2 Figures show defects 3 Controller defect 1 Adjust the mode to proper running 2 Replace the defect LED wire controller and then check the status after...

Page 30: ...verboost C Exploded view 9 Model XHPFDPLUS100E 1 2 3 4 5 6 7 9 12 15 8 14 13 10 11 30 26 29 28 27 25 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 26 44 43 42 41 40 39 56 57 58 59 60 45 46 47 48...

Page 31: ...ght side panel 26 Clip 27 Evaporator temperature sensor d3 TH2 28 Back panel 29 Cable ring 30 Cable connector NO Spare parts 31 Tube 32 Discharge temp sensor d6 TH3 33 Tube 34 Tube 35 EEV 36 Gas tube...

Page 32: ...ump Inverboost C Model XHPFDPLUS160E 1 2 3 4 6 7 8 10 14 13 9 16 15 11 31 27 30 29 28 26 17 18 19 20 21 22 23 24 25 42 43 44 32 33 34 35 45 40 39 38 27 37 36 57 58 59 60 61 53 52 51 50 49 48 47 46 53...

Page 33: ...26 Right side panel 27 Clip 28 Evaporator temperature sensor d3 TH2 29 Back panel 30 Cable ring 31 Cable connector NO Spare parts 32 Tube 33 Low pressure switch 34 Gas return pipe 35 Gas tube 36 High...

Page 34: ...all installed technology of the swimming pool must not be exposed to temperatures below the freezing point It is necessary to remove all water from this whole system technology especially the heat and...

Page 35: ...Swimming Pool Heat Pump Inverboost C 35 Notes...

Page 36: ...Thank you for using ALBIXON products ALBIXON export albixon com www ALBIXON com Note that the photos used in the manual are illustrative only Printing and typesetting errors reserved...

Reviews: