ALBISTONE

®

 G1 BENEFIT/G1 PLUS Skimmer Pools / 

 

7

2.

Preparations for Placement of Miscellaneous Pool Technology. 

Another possible location of the technology is offered by using the ALBIXON technology wall, in its own 
dedicated shaft or in any other place (service room, garden house…). The pool technology should be placed in a 
room with limited access (protected against unauthorized persons or children), where the ambient temperature 
does not exceed 40 °C and where the ambient humidity is suitable for the needs of electrical components.

Where the technology is placed above the water level in 
the pool

, a maintenance (disconnecting) drain shaft should 

be created. Maintenance shaft for convenient disconnection 
of fittings. The disconnect at the lowest point must enable 
draining all water from the shaft system used to drain water 
from the piping for winter. The dimensions of the maintenance 
shaft should be of at least 500 x 500 mm (subject to the 
depth) and the depth should be adequate to the pipe route, 
however always allowing for the convenient disconnection of 
the pipes and discharge of water. For the location of the disconnect fitting, see the picture. The disconnect must 
be placed at the lowest point of the piping.

Technology wall 

(left, right) – a technological unit designed to be 

placed in a service room or in other suitable garden structure. The 
wall must be placed on a horizontal and sufficiently rigid base. On the 
side of the outlets (left or right), it is necessary to leave at least 500 mm 
of space for connections and further handling. To connect the pool 
technology and the pool and – if applicable – external heating, make 
sure to prepare pipeline routes and penetrations of the appropriate 
size (pipe Ø + insulation) into the technology installation space. This 
also applies to technology that is installed atypically.

Install the counterflow device 

separately in the counterflow shaft or in the technology shaft. The counterflow 

shaft should be positioned so that the counterflow pipe from the shaft is aligned with the pool axis and runs towards 
the outlets of the counterflow body placed on the pool shell. This is to achieve the lowest power losses. The 
maximum distance from the exterior contour of the pool shell is 2000 mm.  If the counterflow is not aligned with 
the axis of the pool shell, its performance will be diminished.

Heat pump 

– to connect the pool technology and the heat 

pump, it is necessary to create routes for laying the connecting 
pipe (excavation width 200 mm at minimum, pipe slope 1.5 ° 
along its entire length towards the shaft). To connect the heat 
pump and the technology wall, it is necessary to place the 
disconnectors for water discharge in the maintenance drain 
shaft at the lowest point of the pipe. The heat pump foundation 
slab must be sufficiently firm and level (a concrete foundation 
150 mm high with floor plan dimensions that exceed those of 
the heat pump by at least 40 mm on each side). Install the heat pump in a spacious and sunny location with good 
ventilation. Its position must allow for smooth air circulation; see the instructions for the respective heat pump. 
During its operation, the heat pump may produce a considerable amount of water condensate. This needs to be 
accounted for and drainage must be provided. Ensure that after installation the device is in an upright position 
without any tilt. Do not install the device in places with the presence of contamination or corrosive gases, or where 
dirt or fallen leaves collect. The place where it is installed must not be near flammable or explosive environments 
with usual fire hazards. Observe distances from obstacles, always in accordance with the respective heat pump 
manual. 

Install the heat pump at least 3500 mm from the edge of the pool (according to ČSN 33 2000-7-702) 

and up to 7500 mm from the pool technology and with a vertical difference of up to 1000 mm between the 
water level in the pool and the bottom edge of the heat pump.

 This installation does not result in an excessive 

decrease in the performance of the circulation pump and does not cause heat loss in the longer piping.

Swimming pool

Technology wall

Maintenance shaft for convenient 
disconnection of fittings. 

Discon-

nection at the lowest point must 
drain all water from the system. 

Technology 
shaft/wall

Heat  
pump

Disconnecting 
shaft

Surveying and excavation

Summary of Contents for ALBISTONE G1 BENEFIT

Page 1: ...Skimmer pools ALBISTONE G1 BENEFIT G1 PLUS Version 12 10 2020 Update 31 07 2021 L V Preparation for construction www ALBIXON com...

Page 2: ...om 1 Contents 2 2 Surveying and Excavation 3 3 LevellingtheBottomoftheExcavationandDrainageoftheFoundationSlab 8 4 Concreting of the Foundation Slab 10 5 Notification of Readiness for Construction 11...

Page 3: ...ut of the Pool Excavation Width and Length for the Pool The width and length of the excavation for the pool for the pool placed by a crane 500 mm on each side counted from the outer dimension of the p...

Page 4: ...f the pool 4250 mm 6250 mm 8250 mm L2 foundation slab length 4700 mm 6700 mm 8700 mm L3 excavation length 5250 mm 7250 mm 9250 mm S pool width 3000 mm 2700 mm 3450 mm S1 outer width of the pool 3250 m...

Page 5: ...of the roof This is due to the need to protect the shaft from rainwater If you do not want to have the shaft elevated above the final surface level adequate drainage of rainwater must be provided aro...

Page 6: ...ewage and rainwater system on the premises This will enable the drainage pump and pool technology to be connected directly to the drainage which gives you more comfort in pool maintenance for example...

Page 7: ...ow body placed on the pool shell This is to achieve the lowest power losses The maximum distance from the exterior contour of the pool shell is 2000 mm If the counterflow is not aligned with the axis...

Page 8: ...age pump shaft serves as a sump for collecting groundwater and rainwater It must be provided with a submersible pump This pump must trigger automatically when the water level in the shaft rises and mu...

Page 9: ...olisinslopingterrain or afterbeginningtheearthworks itisfoundthatit hasaclaysubsoil whichmeansahigherprobabilityofgroundwateranditsexercisingof pressureonthepoolbody werecommendthatyouhaveageologicals...

Page 10: ...using a rebar mesh with the dimensions of 100 x 100 x 6 mm It is not necessary to reinforce the foundation slab under the technology shaft 4 Second Layer of Concrete Preparation for Final Layer Now po...

Page 11: ...s trees Choose the type of crane to order accord ing to the weight of the pool and the reach at which the pool is to be placed With great er reach required the lifting capacity of the cranes diminishe...

Page 12: ...on 4 Complete installation of the pool technology Installation of technology and its interconnection via pipes with the pool shell In order to interconnect the pool and the technology shaft correctly...

Page 13: ...you check the wall perpendicularity and flatness and the overall shape of the pool and its diagonals frequently We recommend that the shell should always be braced at the points where reinforcing ele...

Page 14: ...he diagonals of the pool shell In case of any deviation immediately stop the concreting operation and level the shell Concreting is carried out in layers keeping the height of a single layer of concre...

Page 15: ...between the edge of the shaft wall and below the cover These measures are the responsibility of the user Pipes around the technology shaft or to the service room must be laid in a sand bed with a mini...

Page 16: ...tslevelling This plate should be made of monolithic concrete reinforced with rebar mesh 100 x 100 x 6 mm The height of the base plate depends on the height of the type of paving that is chosen Make th...

Page 17: ...m Thermal insulation extruded polystyrene 30 mm Draining pipe Concrete reinforced with rebar mesh Backfill with gravel grain size 8 to 16 mm Backfill with soil Concrete Gravel Raised terrain Dry bulk...

Page 18: ...he edge Mirelon concrete paving concrete crushed aggregate edge tube permanently elastic sealant reinforcing wire slid through the edge Mirelon concrete paving concrete crushed aggregate support prism...

Page 19: ...the values and parameters specified in the report 2 Remeasuring will be carried out by an authorised person in the construction industry the parameters specified in the report are the responsibility o...

Page 20: ...n the report are the responsibility of the authorised person 3 Remeasuring will be made by the ALBIXON a s engineer this service will carry a charge of CZK 5 000 Submission of this duly completed and...

Page 21: ...west passage point gates trees The type of crane or dered according to the pool weight and the reach at which the pool is to be placed Units Units Photo documentation of the preparation for the constr...

Page 22: ...ng to the light earth strip FeZn 30x4 wire 8 mm main protective connection supply cable from the house switchboard c able for connection of filter pump and water management heat pump two cables electr...

Page 23: ...P TO 20M IF THE DISTANCE IS LONGER THE CABLE MUST BE OVERSIZED THE SUPPLY CABLE FROM THE HOUSE SWITCHBOARD TO THE TECHNOLOGY SHAFT MUST BE PROVIDED BY THE CUSTOMER BEFORE THE ORDERED COMPONENTS ARE DE...

Page 24: ...5 The heat exchanger must be connected to the main protective connection HOP Cables for electric heating n CYSY 5 J x 2 5 cable for 3kW heating and 6A 3 B circuit breaker in pool switchboard n CYSY 5...

Page 25: ...circuit breaker C16 1 KM2 heat pump contactor FA3 counterflow circuit breaker C2 1 FA4 lighting transformer circuit breaker C6 1 TR1 safety transformer 230V 12V FU1 fuse insert 2A NF1 light remote con...

Page 26: ...iltration contactor FA2 heat pump circuit breaker C16 1 FA3 lighting transformer circuit breaker C2 1 FA4 external socket breaker B16 1 TR1 safety transformer 230V 12V FU1 fuse insert 2A KT1 filtratio...

Page 27: ...aker C16 1 FA3 counterflow circuit breaker C10 3 KM2 heat pump contactor FA4 lighting transformer circuit breaker C2 1 FA5 socket breaker salt system C6 1 TR1 safety transformer 230V 12V FU1 fuse inse...

Page 28: ...n salt system and heat pump contactor KT1 salt system filtration and heat pump relay timer NF1 light remote control Xl 1 salt system power supply terminal X1 2 filtration motor power supply terminal D...

Page 29: ...ALBISTONE G1 BENEFIT G1 PLUS Skimmer Pools 29 Notes...

Page 30: ...30 ALBISTONE G1 BENEFIT G1 PLUS Skimmer Pools Notes...

Page 31: ...ALBISTONE G1 BENEFIT G1 PLUS Skimmer Pools 31 Notes...

Page 32: ...BIXON Call centre 477 07 07 11 www ALBIXON com The photographs used in this manual are for illustrative purposes only Typesetting and printing errors reserved Thank you for using the products by ALBIX...

Reviews: